Home
Product Catalog
News
Contact Us

Product Catalog 

lab equipment lab furniture eye wash

  • lab equipment lab furniture eye wash
  • lab equipment lab furniture eye wash
  • lab equipment lab furniture eye wash
  • lab equipment lab furniture eye wash
  • lab equipment lab furniture eye wash
Model No.︰RJS-EW-001
Brand Name︰RJS
Country of Origin︰China
Unit Price︰US $ 100 / pc
Minimum Order︰1 pc
Share on:

 Total 20 Related Items 
Prev12345Next

Product Description

Quick Details

Place of Origin:

Guangzhou, China (Mainland)

Brand Name:

RJS

Model Number:

RJSEW

material:

SS

name:

eye wash

Packaging & Delivery

Packaging Details: Carton or plywood packing
Delivery Detail: 7 days

Specifications

Eyewash:
1.Can be used in acidity place
2.Stainless Steel Material
3.Easy to set up
4.factory price

 laboratory use eye wash

Product Description

 

 

1.Passede ISO9001 Quality System Certificate

2.National export and import licensing enterprise

3.China Famous Brand

4.Point enterprise of goverment stocking

 

*Usage

This unit is not only the essential equipment of labor protection, but also the essential facilities against poisonous and corrosive material. If accidents happen, reduce the damage to the minimum degree by quickly spraying or washing the hurt.

*Main function parameters

Pressure

Flux L/Min

Temperature

Nominal

pressure

Seal

pressure

Working

pressure

Shower

Eye

wash

Tepid water

0.4

0.45

0.20-0.40

75.5

11.4

Choosing these data is considering the hurt to the skin, eye(s), when accidents happen.

*Structure

1. The ball valve controls spray and eye wash respectively. It is easily operate and you may assure the quality.

2. Set the seepage hole in the pipe of eye wash, can drain off the residual water in the sprayer head of eye wash, which will help to clean pipes and antifreeze(part of the water drained into the downcomer, will not affect the using.

*Main material: good quality stainless steel, gloss exquisite polished

*Installation and maintenance

  1. You should check the type of products, instruction and the packing list for another time.
  2. The location of the emergency equipment should be installed within 10 seconds walking time or 15 meters from the hazard.
  3. Installation and maintenance:
  4. The connection of the bracket and the pipe: connect the T-piece of outlet with the bracket.
  5. The installation of the bracket: Adjust the position of the T-piece and install it by M10 screw.

The installation of shower pipe: screw on the sprayer head (G3/4 net gasket inside) to sprayer pipe, enwind the other end of sprayer pipe with Teflon tape, tighten at the up part of erect pipe, and then adjust the position of sprayer head and to lock well the

 

1. Body: 304 Stainless steel

 

2. Eye Wash: 304 stainless steel inlet pipe, S/S stay-open ball valve with flag handle & S/S eye wash bowl.

 

3. Spray head: Solid brass, built-in stainless steel filter to remove inpurities from water

 

4. Foot treadle stainless steel available: Activating eye wash valve(Non-standard Supply)

 

  1. Connect the up part and the down part: adjust the direction of up part, connect the up part and down part with union (inside set union gasket), tighten.
  2. Eye wash basin: enwind the screw thread of the outlet with fresh plastic band, connect the down part G1¼ and screw well.
  3. Sprayer: put the G1/2 cushion in the G1/2 screw, and connect with the pipe.
  4. Connect the inlet and outlet pipe, to see if it moves well.

 

*Method of application:

 

1. Please pull down the pull rob, when you need shower, and the shower valve will open; push up the shower switch, the shower valve will close. 

 

2. Please push the board clockwise, when you need eye washing, and the facility will work, pullback the push board withershins, eye wash valve close. 

 

3. The silt, residue flax, iron and other debris in the pipeline must be cleared before installation, avoid to block sprayer head or damaged sealing parts, causing the valve could not close strictly.

 

*Maintenance

 

1. Should using the facility above zero environments, and you should notice the pipeline antifreeze if used in the cold place. 

 

2. Please clean the inert pipeline before installation. 

 

3. suggest to install the main valve in the inlet pipe, close the main valve first after using, and close the shower/eye wash valve when clear up the remain water. 

Payment Terms︰TT/ LC/ Money gram/ western union/ paypal
Product Image






Related Products
chemical brass lab water tap
chemical brass lab water tap
US $ 50
School Laboratory use Durable steel cupboard medical storage cabinet
School Laboratory use Durable steel cupboard medical storage cabinet
US $ 350
laboratory chemical reagent storage cabinets
laboratory chemical reagent storage cabinets
US $ 350
Laboratory polypropylene epoxy resin sink
Laboratory polypropylene epoxy resin sink
US $ 75




Home  |  Product Catalog  |  News  |  Contact Us  |  Sitemap  |  Mobile Version

Powered by DIYTrade.com  Build your FREE website !
Find Best Price For China Products !